What Is a FeNO Machine?
A FeNO machine, also called a FeNO analyser or FeNO testing device, measures the concentration of nitric oxide in exhaled breath. Results are expressed in parts per billion (ppb).
Elevated FeNO levels can be associated with type 2 airway inflammation, which occurs in certain forms of asthma.
The BTS/NICE/SIGN asthma guideline incorporates FeNO testing into defined asthma diagnostic pathways, while the American Thoracic Society provides guidance on interpreting FeNO measurements.
FeNO testing complements investigations such as spirometry and clinical assessment. It does not independently diagnose asthma or identify every type of airway inflammation.
What Types of FeNO Machines Are Available?
Healthcare organisations can evaluate several types of FeNO measuring equipment.
| Device type | Typical application | Key considerations |
|---|---|---|
| Professional FeNO analyser | Respiratory clinics and hospitals | Measurement performance, throughput, data management |
| Portable FeNO machine | Outpatient and decentralised clinical settings | Mobility, ease of operation, connectivity |
| Personal FeNO monitor | Supervised home monitoring | Patient usability, data recording, clinical oversight |
| Connected FeNO system | Clinics and structured monitoring programmes | Electronic records, data sharing, software integration |
These categories can overlap, as a professional FeNO analyser may include a portable handheld component, while a home-monitoring device may support digital data collection.
The appropriate equipment depends on how and where measurements will be performed.
What Should You Consider When Choosing a FeNo Machine for Your Clinic?
1. Evaluate Measurement Accuracy and Reliability
Measurement reliability should be a primary consideration when choosing a FeNO machine.
Healthcare buyers should investigate:
- Published device validation studies.
- Measurement repeatability and accuracy.
- Applicable ATS/ERS measurement standards.
- Quality-control procedures.
- Calibration and sensor maintenance requirements.
For example, Bosch reports that its Vivatmo Pro system has demonstrated clinical equivalence to chemiluminescence measurement methods, referencing published validation studies.
Healthcare professionals should review the underlying evidence and device documentation rather than relying solely on manufacturer descriptions.
2. Consider Patient Comfort and Ease of Use

A FeNO test requires the patient to breathe into a device using a controlled exhalation manoeuvre.
For some patients, particularly younger children, completing the measurement correctly may require additional guidance.
Equipment that provides clear visual or audio instructions can help patients follow the procedure.
The Bosch Vivatmo pro system incorporates live visual guidance during testing.
According to Bosch’s Vivatmo System brochure, its standard measurement mode involves a 10-second exhalation. A 6-second mode is available for children aged 7–11 who cannot complete the standard manoeuvre.
When evaluating a FeNO machine, clinics should confirm the manufacturer’s age restrictions and instructions for use.
3. Understand FeNO Machine Maintenance and Calibration
Maintenance requirements can influence the long-term cost and practicality of FeNO equipment.
Some devices may require periodic calibration, sensor replacement or other servicing, depending on their technology and design.
Healthcare buyers should establish:
- Whether recalibration is required.
- Whether sensors need replacing.
- The stated device or sensor lifetime.
- Any scheduled servicing requirements.
- Quality-control procedures and associated costs.
A. Bosch Vivatmo Pro: Maintenance-Free Sensor Technology

Bosch describes the Vivatmo Pro sensor as factory-calibrated and maintenance-free throughout its specified product lifetime.
Its brochure states that Vivatmo pro supports 5,000 measurement trials without recalibration or sensor maintenance.
This is a potentially important operational consideration for clinics seeking to reduce routine equipment servicing.
However, maintenance-free sensor technology does not eliminate the need for disposable mouthpieces, appropriate quality-control procedures or compliance with manufacturer instructions.
The stated measurement-trial lifetime should also be distinguished from the number of successfully completed patient tests.
4. Calculate the Total Cost of FeNO Testing Equipment
The purchase price is only one component of the cost of introducing FeNO testing.
A healthcare facility should consider the total cost of ownership over the expected period of use.
| Cost component | Questions for procurement teams |
|---|---|
| Equipment purchase | What is included in the initial quotation? |
| Disposable mouthpieces | What is the cost per measurement attempt? |
| Sensor replacement | Is replacement required during the stated lifetime? |
| Calibration | Are recalibration services or accessories necessary? |
| Maintenance | Are servicing contracts or repairs required? |
| Training | What staff training is included? |
| Software | Are data-management or integration costs applicable? |
| Technical support | Is support available in the intended country? |
For clinics performing regular FeNO measurements, recurring consumable expenses can be particularly important.
A useful purchasing exercise is to estimate the number of measurements expected each month, then calculate equipment and operating costs over several years.
The cheapest initial equipment price does not necessarily represent the lowest long-term cost.
5. Check Disposable Mouthpieces and Infection-Control Features

FeNO testing involves patients breathing into a measurement device, making disposable accessories and hygiene procedures important.
The Bosch Vivatmo system uses the Vivatmo oxycap, a disposable mouthpiece designed to prepare the breath sample and support device hygiene.
- According to Bosch, its multilayer construction includes components for managing moisture and interfering substances, together with a germ filter.
- The manufacturer states that the mouthpiece blocks more than 99.9% of bacteria and viruses from entering the device.
This is a manufacturer-reported filtration characteristic, not a guarantee that the complete testing process eliminates infection risk.
Before purchasing, confirm the availability, pricing and expected consumption of compatible mouthpieces.
6. Consider Patient Throughput and Clinical Workflow
A FeNO machine should fit into the clinic’s existing appointment structure.
Important operational questions include:
- How long does a complete patient testing appointment take?
- How frequently do patients need to repeat a measurement?
- Can staff operate the device with minimal disruption?
- Can measurements be performed in different consultation rooms?
- How are patient results recorded and retrieved?
For larger respiratory services, even small differences in preparation time, testing procedures and record-keeping may affect workflow efficiency.
Portable handheld equipment can also be useful where FeNO testing is performed across multiple clinical locations.
However, throughput should be assessed using the complete workflow rather than the exhalation time alone.
7. Evaluate Electronic Patient Record Integration
Digital connectivity is increasingly relevant when hospitals and clinics evaluate diagnostic equipment.
Manually transferring test results into electronic records can create additional administrative work and opportunities for transcription errors.
Healthcare buyers should investigate whether a FeNO machine can communicate with their existing systems.
Vivatmo Pro Connectivity
Bosch lists several connectivity options for Vivatmo pro, including:
- USB – 2 ports on the base station support connecting an external printer for immediate test printouts and exporting patient files (such as PDF reports) directly to a USB flash drive.
- Wi-Fi – Built-in 2.4 GHz (802.11 b/g/n) wireless connectivity allows network integration without a physical LAN cable, as well as remote software updates via Bosch’s Vivasuite solution.
- Ethernet – A wired 10/100 MB LAN port connects the base station to a clinic’s local network. Per the Vivatmo pro Instructions for Use, this port requires a network with galvanic isolation certified to EN 60601-1 (or an external EN 61010-1 network isolator) for electrical safety.
- HL7 – The international messaging standard used in hospitals and larger healthcare systems to receive patient worklists/orders and send FeNO results directly into Electronic Medical Records (EMR).
- GDT (Gerätedatentransfer) – A standardized device data-transfer protocol commonly used by Practice Management Systems (PMS) in Germany and European outpatient clinics for bidirectional data exchange between medical devices and practice software
For hospitals using electronic patient records, these capabilities may be valuable.
Nevertheless, compatibility should be confirmed with the organisation’s IT department, including supported interfaces, software versions, cybersecurity requirements and any additional implementation costs.
8. Should Your Clinic Consider Home FeNO Monitoring?
Professional FeNO testing is generally performed during clinical appointments.
However, some healthcare organisations may also be interested in collecting measurements between visits.
Bosch’s Vivatmo Me is a personal FeNO monitoring device designed for home use.

The brochure describes a lifetime of 1,000 measurements without recalibration or sensor maintenance, together with Bluetooth data transfer to the Vivatmo app.
- Patients can record FeNO measurements alongside information such as symptoms, medication use and environmental triggers.
This may provide additional information for clinicians supervising selected asthma patients.
Home FeNO monitoring should be introduced through an appropriate clinical programme. Measurements do not replace medical assessment or justify independent changes to prescribed treatment.
Bosch Vivatmo Pro for Clinical FeNO Testing
For healthcare providers evaluating professional FeNO equipment, Bosch Vivatmo Pro is one option worth considering.
The system combines handheld FeNO measurement with a base station designed for clinical use.
Its main manufacturer-described features include:
| Vivatmo Pro Feature | Potential Relevance to Healthcare Providers |
|---|---|
| 5,000 measurement-trial lifetime | Supports planning for equipment utilisation |
| No sensor recalibration during stated lifetime | May reduce routine maintenance requirements |
| Visual measurement guidance | Helps patients complete the breathing manoeuvre |
| Portable handheld | Supports testing across suitable clinical locations |
| Electronic patient record connectivity | May simplify clinical data management |
| Disposable oxycap mouthpiece | Supports sample preparation and device hygiene |
These features may be relevant to respiratory specialists, asthma clinics, outpatient departments and hospitals evaluating point-of-care FeNO testing.
The suitability of the system will depend on the intended patient population, clinical requirements, available budget and local regulatory authorisation.
Further product information is available through the official Bosch Vivatmo website.
Questions to Ask Before Purchasing a FeNO Machine
Before selecting equipment, healthcare procurement teams should request clear answers to the following:
- Is the device authorised for the intended clinical use and patient population in our country?
- What evidence supports its measurement performance?
- How many measurement attempts can the device perform during its stated lifetime?
- What consumables are required, and what do they cost?
- Does the equipment require calibration, sensor replacement or servicing?
- Can the device integrate with our electronic patient records?
- What training and technical support are available?
- What is the estimated total cost of ownership?
These questions can help healthcare organisations compare available technologies and identify equipment suited to their operational requirements.
Interested in a FeNO Machine for Your Clinic or Hospital?
Introducing FeNO testing can provide healthcare professionals with an additional objective measurement to support asthma assessment and monitoring.
At MediDiagAfrica, we explore respiratory diagnostic technologies for hospitals, clinics and healthcare organisations, including Bosch Vivatmo FeNO measurement solutions.
Whether you are planning to introduce FeNO testing, evaluating equipment for an existing respiratory service or exploring home-monitoring applications, we welcome enquiries about your requirements.
Considering Bosch Vivatmo pro for your healthcare facility?
We welcome enquiries from respiratory specialists, hospital administrators, clinic managers and medical equipment procurement teams.
Product availability, intended use and regulatory authorisation vary by country. Equipment specifications should be confirmed against the applicable manufacturer’s instructions and local supply arrangements.
